4....MILITARY SURPLUS MBU BURNERS +POWER UNIT+CORD ARMY FIELD KITCHEN CAMP ARMY For Sale
When you click on links to various merchants on this site and make a purchase, this can result in this site earning a commission. Affiliate programs and affiliations include, but are not limited to, the eBay Partner Network.
4....MILITARY SURPLUS MBU BURNERS +POWER UNIT+CORD ARMY FIELD KITCHEN CAMP ARMY:
$1795.00
4....MILITARY SURPLUS MBU BURNERS +POWER UNIT+CORD ARMY FIELD KITCHEN CAMP ARMY
sale IS FOR...4...FOUR... TOTAL MBU BURNERS...ONEMBU POWER UNIT ....ORIGINALMILITARY POWER CABLE....GOOD CONDITION V3 BURNERS
312 ,144 ,205 ,594 HOURS ON THE 4 MBU BURNERS...ALL 4 BURNERS ARE V3 OR LATEST VERSION...ALL HAVE BEEN TESTED AND DRAINED OF FUEL
LAST PICTURE IS FROM ANOTHER sale SHOWING 4 BURNERS LIT...NOTHING ELSE FROM THE LAST PICTURE IS INCLUDED,JUST THERE FORREFERENCE
NOTE*** SELLING THIS AS A SET ,NOT SELLING ANY INDIVIDUAL PART
UPS SHIPPING LOWER 48 STATES...FLAT RATE $195..WILL BE AT LEAST 2 BOXES
IDO NOT SELL U.S SURPLUS OUTSIDE THE U.S.....THANKS
THANKS FOR LOOKING
SALES TAX COLLECTED FOR MISSOURI RESIDENTS ....5.475 %
COLLECTS SALES TAX ON SOME OTHER STATES AS WELL..THIS IS THERE STATEMENT...."we collect sales tax in accordance with applicable state law.you no longer need to collect and pay it to the state" ...SO... YOU MIGHT CHECK THE SHIPPING TAB TO SEE IF SALES TAX IS COLLECTED IN YOUR AREA
MBU BURNER TIPS
couple of tips …mbu burners take a bit to prime,…start with the power button ,if they power up,you have the cables correctly,and tight enough…then the start button,if it immediately goes to “service” hit the stop button..wait a second then hit the start again..you may have to repeat this a few times to prime them…watch the setting -knob-on the burner for startup (center front of the unit),they do better if they are higher( but not all the way high) not lower to start…” usually “ not always…they will sputter and smoke off and on through the warm-up phase,they will even somewhat -shut off -and smoke from the fuel mist not being ignited ,they will either re-ignite or go to “service” if they go to service then just start over…all of this is normal…they will eventually stabilize and burn constant,then you can turn them down….i would change the fuel every year if they are stored not used with fuel in them…last ….zero hour burners are good,but need to be used -broke in a bit more…the 25-45 hour burners are a good break in hour burner..have seen several hundreds of hour burners work fine,some of the higher hour burners have worked the best over the years..there is a manual for these,but these would be the highlights